High accuracy
High cycle life
Submersible
Stainless steel
Infinite resolution
Miniature
These transducers are for displacement / position measurement. They make an accurate position measurement of the movement of the armature (the sliding part) relative to the body of the displacement transducer.
This transducer uses the Linear Variable Differential Transformer (LVDT) principle which means that it is probably the most robust and reliable position sensor type available. The strength of the LVDT sensor's principle is that there is no electrical contact across the transducer position sensing element which for the user of the sensor means clean data, infinite resolution and a very long life.
Our submersible displacement transducers are designed to make measurements whilst submerged in suitable liquids. Fluids which are non-magnetic can be allowed to flood the armature tube without affecting the operation of the transducer.
The LVDTs are available as either unguided or spring return versions.
This transducer uses the Linear Variable Differential Transformer (LVDT) principle which means that it is probably the most robust and reliable position sensor type available. The strength of the LVDT sensor's principle is that there is no electrical contact across the transducer position sensing element which for the user of the sensor means clean data, infinite resolution and a very long life.
Our submersible displacement transducers are designed to make measurements whilst submerged in suitable liquids. Fluids which are non-magnetic can be allowed to flood the armature tube without affecting the operation of the transducer.
The LVDTs are available as either unguided or spring return versions.
Unguided version.
On our D5W unguided LVDTs the armature assembly is a separate component, to make a measurement the user must guide the armature inside the body without touching the sides. Our D5W unguided position measurement transducers are appropriate where external guidance is available and give truly non-contact operation
End (axial) exit cable.
D5/40W D1=0.315'' (0.3136'' to 0.3146'')
D5/100W to MD5/500W D1=0.374'' (0.370'' to 0.374'')
D3=0.079''
TGF=M3x0.5
X=Center of range
Side (radial) exit cable.
D5/40WRA D1=0.315'' (0.3136'' to 0.3146'')
D5/100WRA to MD5/500WRA D1=0.374'' (0.370'' to 0.374'')
A=0.3'' (nominal)
CL1=0.7''
D3=0.079''
TGF=M3x0.5
X=Center of range
Spring return version.
Our D5W spring displacement transducer has bearings to guide the armature inside the measurement sensor and a spring which pushes the armature to the fully out position. Our D5W spring return LVDTs are appropriate where it is not possible to connect the transducer armature to the moving component being measured.
End (axial) exit cable.
D5/40AW
D1=0.315'' (0.3136'' to 0.3146'')
D2=0.28''
D3=0.156''
L2=0.29''
D1=0.315'' (0.3136'' to 0.3146'')
D2=0.28''
D3=0.156''
L2=0.29''
D5/100AW to MD5/500AW
D1=0.374'' (0.370'' to 0.374'')
D2=0.31''
D3=0.187''
L2=0.31''
D1=0.374'' (0.370'' to 0.374'')
D2=0.31''
D3=0.187''
L2=0.31''
X=Center of range
Side (radial) exit cable.
D5/40AWRA
D1=0.315'' (0.3136'' to 0.3146'')
D2=0.28''
D3=0.156''
L2=0.29''
D1=0.315'' (0.3136'' to 0.3146'')
D2=0.28''
D3=0.156''
L2=0.29''
D5/100AWRA to MD5/500AWRA
D1=0.374'' (0.370'' to 0.374'')
D2=0.31''
D3=0.187''
L2=0.31''
D1=0.374'' (0.370'' to 0.374'')
D2=0.31''
D3=0.187''
L2=0.31''
A=0.3'' (nominal)
CL1=0.7''
X=Center of range
Specification
Options and accessories
TM0315 Operating temperature range (maximum) = 392℉ ( (On some models) ) | |
Mounting block for RDP transducers | |
E74 In-Line LVDT Amplifier ( Depending on cable type ) | |
Amplifiers | |